Units are designed in accordance with NFPA 70 (National Electric Code),ASHRAE/ANSI 15 Safety code for mechanical refrigeration,ASME, Listed and labeled with Intertek Testing Services (ETL) and rated in accordance with ARI Standard 550/590-2003. Corrosion resistant wire mesh panels are added to protect the condenser coil from incidental damage and restrict unauthorized access to internal components. The unit structure is heavy-gauge, galvanized steel.This galvanized steel is coated with baked-on powder paint, which, when subjected to ASTM B117 1000 hour, salt spray testing, yields a minimum ASTM 1654 rating of “6”. After assembly, a complete operational test is performed with water flowing through the cooler to assure that the refrigeration circuit operates correctly. The unit is pressure-tested, evacuated, and fully charged with Refrigerant-22 (HCFC-22) and includes an initial oil charge. The 47 - 60 Ton (165 - 210 kW) YCAL models are shipped complete from the factory ready for installation and use.

york ycal low ambientkit

Power Wiring.Ĭontrol Wiring.Īpplication Data.

#York ycal low ambientkit download#

Isolator Details (cont'd).Įlectrical Data.Įlectrical Data - 60Hz.Įlectrical Data - 50Hz. york ycal0014sc, ycal0080sc table 46 microboard outputs, table 44 microboard binary inputs, table 45 microboard analog inputs, sys 1 low press switch 1 136 Download 136 pages, 3. Sound Data.ĭimensions - YCAL0041 (English).ĭimensions - YCAL0045 (English).ĭimensions - YCAL0051 (English).ĭimensions - YCAL0055EC - (English).ĭimensions - YCAL0061 (English).ĭimensions - YCAL0065 (English).ĭimensions - YCAL0041 (SI). Part Load Ratings - R-22 (English Units). Ratings - R-22 (50Hz - English Units) - Cont. Ratings - R-22 (60Hz - English Units) - Cont. This item is restricted for international sale.

york ycal low ambientkit

Under this Certification Program, chillers are regularly tested in strict compliance with this Standard. This product has been certified by a third party to be compliant with the Safe Drinking Water Act requirements for low lead in potable (human consumption - drinking and cooking) and non-potable water applications (non-human consumption).

  • Part Load Ratings - R-22 (English Units)įORM 150.64-EG1 (405). Minimum operating ambient temperature (with optional low-ambient control), -20 C. YORK YCAL chillers have been tested and certified by Air-Conditioning, Heating and Re - frigeration Institute (AHRI) in accordance with the latest edition of AHRI Standard 550/590 (I-P).
  • Ratings - R-22 (50Hz - English Units) - Cont.
  • Ratings - R-22 (60Hz - English Units) - Cont.
  • Renewal PaRts aIR-COOleD lIQUID CHIlleRs HeRMetIC sCROll Supercedes: 150.67-RP1 (310) Form: 150. If there is any question in the mind of operating/ service personnel as to the applicability of these documents, then, prior to working on the equip-ment, they should verify with the owner, whether the equipment has been modified and if the current litera-ture is available.

    york ycal low ambientkit

    #York ycal low ambientkit update#

    While Johnson Controls makes no commitment to update or provide current information automatically to the manu-al user, that information, if applicable, can be obtained by contacting the nearest Johnson Controls Engineered Systems Service is the responsibility of operating/service personnel as to the applicability of these documents to the equip-ment in question. Chiller, 110 ton Air cooled Shell and tube heat exchange 2007 vintage. Renewal PaRtsaIR-COOleD lIQUID CHIlleRsHeRMetIC sCROllSupercedes: (310)Form: (511)MODels YCal0019, 0022, 0028, 0033, 0043, 0046, 0052,0056, anD 00380/415-5046 0-3-6 MODELS ONLYR-410A15 - 60 TON53 - 218 Kw50Hz and 60Hz50091stYle "e"Issue Date:JOHNSON CONTROLS2 FORM (511)ISSUE DATE In complying with Johnson Controls policy for con-tinuous improvement, the information contained in this document is subjected to change without notice. Chiller, 140 ton Air Cooled 138.8 TR capacity BAS Int.